QUICK

Seongmo Dental Clinic · Seongbuk-gu, Seoul

T-scan · Digital Occlusal Analysis

"Just bite on articulating paper" — that alone can't tell you everything.

Now we see occlusion as data, down to 0.003 seconds
.

Seongmo Dental Clinic measures bite force, contact timing, and per-tooth load in real time with the T-scan digital occlusal analysis system. Timing sequence and force distribution that articulating paper can't show are visualized on a color graph, letting us manage the causes of tooth fracture, TMJ disorder, and implant failure with data.

Sungshin Univ. Seongmo Dental Clinic Digital Occlusal Analysis (T-scan)

Measurement Unit
0.003 sec
Contact-Timing Analysis
Analyzes
Force · Sequence · Load
Quantified Per Tooth
Used For
Restorations/Implants
Precision Bite Adjustment
Occlusion is the start and finish of every dental treatment. We check invisible forces with data.
Method
Sensor-Based Digital Occlusal Analysis
Resolution
Measured in 0.003-second increments
Analyzes
Bite Force · Timing · Load Distribution
Application
Restorations/Implants/TMJ/Bruxism
01
What is T-scan

Digital occlusal analysis —
what does it measure?

T-scan is a device that measures the force, contact order, and timing difference on each tooth when you bite down on a thin sensor — down to 0.003 seconds — and visualizes it on screen.

0.003 sec
Measurement Unit
Color Graph
Force Distribution Visualized
Real-Time
See Adjustments Instantly

Occlusion is how your upper and lower teeth meet. Even a very slight imbalance can cause tooth fracture, TMJ disorder, implant failure, or a restoration coming loose. Traditionally, this was checked only with articulating paper (thin carbon paper), making it hard to know exactly how much force landed on which tooth, when, and in what order.

The T-scan Seongmo Dental Clinic uses measures bite force, contact timing, and per-tooth load in real time and visualizes it on screen. Occlusal problems that used to be invisible are now identified with data and resolved scientifically.

T-scan — Core Technology

Real-Time Bite Force & Timing Analysis
Contact order and force are measured down to 0.003 seconds. Timing sequence and force distribution that articulating paper can't reveal are visualized on a color graph for precise diagnosis.
Precision Bite Adjustment for Implants & Restorations
Occlusal adjustment after seating a restoration is central to treatment success. Checking excess bite load as a number allows precise adjustment that helps prevent restoration fracture, loosening, and peri-implantitis.
Improved Precision in TMJ Treatment
Identifies occlusal imbalance, one cause of TMJ disorder, and provides objective evidence when making and adjusting a splint. Before/after can be compared numerically.
Minimizes Tooth Reduction & Occlusal Adjustment
Guides adjustment to only the areas that actually need it, minimizing unnecessary tooth reduction.
Diagnosing Bruxism (Grinding/Clenching)
Analyzes overload patterns with data, giving an objective basis for deciding on a night guard or Botox treatment.
Transparent Bite Consultation With the Patient
We review the analysis together on screen. You understand the need for treatment from data, not just how it feels.

Resolving even invisible occlusal problems with data raises the long-term success rate of implant, restorative, and TMJ treatment.

02
Prosthetics

Why a new restoration feels off —
it's usually the bite

If a restoration contacts before other teeth, or force concentrates on one spot, it can lead to sensitivity, fracture, loosening, or bone loss around an implant. T-scan checks this load as a number and adjusts accordingly.

Premature Contact
Early-contact points identified
Concentrated Load
Confirmed as a number
Verified Adjustment
Before/after comparison

Unlike a natural tooth, an implant can't absorb force through micro-movement. So excess load on an implant restoration can lead to a loose screw, restoration fracture, or bone loss around it.

Seongmo Dental Clinic checks occlusion with T-scan even after seating a same-day Primemill restoration. As much as scan and milling precision matter, the final bite adjustment is what determines the restoration's lifespan.

If you notice these symptoms

Sensitivity or pain after a new restoration
We check for premature contact or excess load.
A restoration keeps chipping or coming loose
We analyze the direction and magnitude of force to find the cause.
Gum swelling recurs around an implant
We manage bite load together with Q-ray/powder cleaning for inflammation.

The final step of a restoration is occlusal adjustment.

03
TMJ & bruxism

TMJ and bruxism —
we look at the pattern of force

Occlusal imbalance places ongoing strain on the jaw joint and muscles. T-scan data becomes objective evidence for designing and adjusting a splint, and for deciding on Botox treatment.

Load Pattern
Left-right balance checked
Splint
Basis for design & adjustment
Before/after comparison
Treatment effect confirmed

Jaw stiffness in the morning, temple pain, or tooth sensitivity without decay can be caused by bruxism/clenching and occlusal overload.

Seongmo Dental Clinic checks force distribution with T-scan, fabricates splints/ARS with our in-house 3D printer, and if needed, reduces muscle strain with i-JECT B precision-dose Botox. We compare before and after with numbers to confirm the effect.

TMJ Treatment Flow

01 — Occlusal & Joint Diagnosis
T-scan analysis and 3D CT confirm force distribution and joint condition.
02 — Appliance or Botox
Splints/ARS are fabricated in-house, or precision-dose Botox is considered for muscle overactivity.
03 — Re-measure & Adjust
Occlusion is re-measured and adjusted step by step as it progresses.

We turn adjustments once made by feel into adjustments made with data.

04
Minimal adjustment

Occlusal Adjustment
That Removes Less Tooth

Knowing exactly where and how much to adjust as a number lets us refine only the necessary contact points instead of broadly grinding down tooth structure, preserving it.

Contact Point Identified
Minimal Adjustment Range
Instantly Verified
Re-measured After Adjustment
Structure Preserved
Unnecessary reduction avoided

Adjusting with articulating paper alone makes it hard to know whether every marked spot needs grinding, which can lead to over-adjusting a tooth more than necessary.

T-scan shows exactly where and in what order force concentrates, so balance can be achieved with minimal adjustment. Seongmo Dental Clinic runs this as part of our natural-tooth-preserving philosophy.

Treatments Used Together

Restoration After Plasma Root Canal Treatment
A root-treated tooth is more fracture-prone, making bite-load management important.
Veneers & Esthetic Restorations
We check anterior contact sequence to reduce the risk of chipping.
Finishing After Orthodontics
Occlusal balance is checked once tooth alignment is complete.

The best adjustment is the one that removes the least.

Comparison

Articulating Paper vs. Digital Occlusal Analysis

ComparisonArticulating PaperSeongmo Dental Clinic T-scan
Information ShownContact LocationLocation + Force + Order + Timing
Timing AnalysisNot possibledown to 0.003 seconds
Force MagnitudeEstimatedQuantified as a number
Left-Right BalanceSubjective judgmentGraph comparison
Verified AdjustmentRepeated checkingInstantly re-measured after adjustment
Explaining to the PatientVerbal explanationReviewed together on screen

Occlusion changes over time and with habits. Periodic reassessment may be needed.

Glossary

Occlusal Analysis — Glossary

Occlusion
How and where the upper and lower teeth meet.
Premature Contact
A contact point that touches before others, concentrating force there.
Occlusal Overload
A state where excess force repeatedly lands on a specific tooth or restoration.
Bruxism
The habit of grinding or clenching teeth.
Splint
An appliance worn to manage occlusal and muscle strain.
Peri-implantitis
Inflammation of the gum/bone around an implant; excess occlusal load can be a risk factor.
FAQ

Sungshin Univ. Digital Occlusal Analysis — FAQ

How is a T-scan exam done?

With a thin sensor between your teeth, you bite as you normally would, and the force and contact order on each tooth appear on screen in real time. There's no pain or radiation exposure.

Is it really different from adjusting with articulating paper?

Articulating paper only shows where teeth touch. T-scan also shows how hard and in what order, letting us pinpoint exactly where to adjust.

I have an implant — do I need an occlusal exam?

Unlike a natural tooth, an implant has little cushioning to absorb force, making it vulnerable to overload. Checking occlusion after placement and at regular checkups helps manage implant lifespan.

Does this help with bruxism treatment?

Occlusal overload patterns are checked with data as a basis for deciding on a night guard or Botox treatment, and before/after comparison is also possible.

Once adjusted, does it stay that way?

Occlusion can change with tooth wear, restoration changes, and habits. If symptoms appear, we re-measure and adjust.

What does the exam cost?

Coverage for exam and adjustment depends on the clinical context. See our non-covered fee guide for self-pay items, and we'll explain at diagnosis.

References

References — Authoritative Medical Sources

Related Treatment Info

Results of any dental treatment can vary with individual oral condition, and whether a device applies depends on the case. Treatment method should be decided after a precise diagnosis and thorough consultation with your provider.